Buy KPV 10mg + bacteriostatic water
€41.64
KPV, 10 mg, with bacteriostatic water, is a synthetic Lys-Pro-Val tripeptide format for analytical and in vitro laboratory research. Pharma Research .eu provides documented European supply subject to lot-specific purity and identity verification.
Buy KPV, 10 mg + Bacteriostatic Water, for Advanced Laboratory Research in Europe
KPV is a synthetic tripeptide comprising lysine, proline and valine, commonly written as Lys-Pro-Val or K-P-V. It corresponds to residues 11–13 of α-melanocyte-stimulating hormone and is used as a laboratory reagent in peptide analytics, biochemical assay development and controlled in vitro investigations. The commonly reported formula is C₁₆H₃₀N₄O₄, with an average molecular mass of approximately 342.43 Da. Pharma Research .eu presents this 10 mg format with bacteriostatic water for qualified European laboratory teams.peptidebiologix+2
Uncompromising Purity and Analytical Characterisation
KPV should be specified as the linear tripeptide:
H-Lys-Pro-Val-OH
The terminal groups are important. The commonly referenced research material has a free N-terminus and free C-terminal carboxylic acid. Acetylated, amidated, salt-form or otherwise modified variants should not be treated as interchangeable because they may have different molecular masses, charge states, chromatographic retention and assay behaviour.
For laboratory procurement, the suitable target is ≥99.0% purity by RP-HPLC, subject to confirmation by the actual lot-specific certificate of analysis. Some commercial research listings report ≥99% HPLC purity with CoA documentation, but the batch chromatogram and identity data should be reviewed before acceptance.biolongevitylabs+1
A complete CoA should include:
-
RP-HPLC purity percentage, method and chromatogram.
-
LC-MS, ESI-MS or high-resolution MS identity confirmation.
-
Peptide sequence and terminal-group designation.
-
Free-peptide, acetate or other salt-form information.
-
Molecular mass and principal molecular-ion assignment.
-
Appearance of the lyophilised material.
-
Residual-solvent results from synthesis and purification.
-
Water or residual-moisture content, where measured.
-
Heavy-metal or elemental-impurity results where included in the quality programme.
-
Lot number, manufacture date, retest date and storage requirements.
The commonly reported formula is C₁₆H₃₀N₄O₄, with an average molecular mass of approximately 342.43–342.44 g/mol and a monoisotopic mass near 342.2267 Da. Public and commercial references show inconsistent CAS assignments for KPV, so the supplier should reconcile the sequence, formula, molecular mass and registry number on the CoA.peptidebiologix+2
KPV is generally supplied as a white to off-white lyophilised powder. Visual inspection can identify gross discolouration, vial damage or visible contamination, but it cannot confirm purity or identity. Analytical release should combine visual examination with RP-HPLC and mass-spectral testing.
High purity is important because small peptides can be affected by deletion products, altered terminal groups, residual synthesis materials, counter-ions and water content. Such components may alter peak integration, ionisation efficiency, apparent concentration and recovery during sample preparation. Lower-grade or non-characterised material may therefore be unsuitable for quantitative LC-MS, stability-indicating assays or publication-quality comparisons.
Bacteriostatic water is a separate reagent and should have its own label, expiry date, formulation details and documentation. Preservatives can influence chromatographic background, ion suppression, adsorption, pH and cellular assay performance.
Principal Laboratory Applications and Research Methodologies
KPV is suitable for controlled laboratory research involving small-peptide chemistry, analytical characterisation and in vitro biochemical models. All applications should be conducted by qualified personnel within an appropriately governed university, CRO, pharmaceutical R&D or analytical laboratory.
RP-HPLC and LC-MS method development. KPV can be used as a defined low-molecular-weight peptide analyte for retention-time assignment, chromatographic optimisation and mass-spectral method development. Its small size and ionic functional groups may require careful optimisation of mobile phase, pH, column chemistry and sample concentration.
Reference and system-suitability work. A characterised KPV lot may support instrument checks, sample-preparation recovery experiments, calibration development and inter-run comparison. Unless formally certified under a recognised reference-material standard, it should be described as a research reference material or analytical reagent rather than a certified reference material.
Peptide stability studies. Laboratories may investigate the influence of temperature, light, pH, oxidation, moisture, container material and freeze–thaw history. Stability studies should distinguish true chemical degradation from adsorption to laboratory plastics, incomplete dissolution or analytical carryover.
In vitro biochemical investigations. KPV may be incorporated into cell-free or cellular assay systems to study peptide-associated biochemical responses. Experimental plans should include vehicle controls, matrix blanks, concentration confirmation and testing of the bacteriostatic-water formulation independently where relevant.
The 10 mg quantity corresponds to approximately 29.2 µmol using the reported average molecular mass of 342.43 g/mol. No final concentration should be stated because the volume of bacteriostatic water was not specified. The actual concentration depends on the final volume, peptide purity, moisture content, terminal groups, counter-ion and validated preparation method.
Bacteriostatic water should not automatically be assumed appropriate for every analytical or cellular workflow. Its preservative content may require solvent blanks, matrix-effect testing or cell-compatibility assessment. Laboratories should select and validate the reconstitution medium for the intended method.
Compound Stability, Optimal Storage, and Safe Handling Protocols
KPV should remain sealed in its lyophilised form until required for a validated laboratory procedure. Research references commonly recommend storing the dry peptide at −20°C in a sealed, dry, light-protected container. Short-term refrigerated storage may be acceptable when supported by the product documentation, but no universal shelf-life should be claimed without lot-specific stability data.peptidebiologix+2
Recommended controls include:
-
Store unopened lyophilised KPV at approximately −20°C unless the CoA specifies otherwise.
-
Keep the container tightly closed, dry and protected from direct light.
-
Allow a sealed vial to reach room temperature before opening to minimise condensation.
-
Use low-binding tubes when adsorption could affect recovery.
-
Prepare aliquots if repeated access could expose the material to moisture or contamination.
-
Store short-term aqueous solutions at 2–8°C only when validated.
-
Use frozen aliquots for longer-term solution storage where supported by stability data.
-
Avoid repeated freeze–thaw cycles.
-
Record solvent, concentration, preparation date, operator and storage history.
KPV’s small size does not guarantee unlimited solution stability. Prepared solutions may experience adsorption, pH-dependent changes, hydrolysis or microbial-risk concerns depending on the medium and storage duration. The research group should verify concentration and chromatographic integrity after storage rather than relying only on visual appearance.
Reconstitution should be carried out using a validated laboratory procedure. Add the aqueous reagent gradually, allow the powder to hydrate and mix gently. Avoid vigorous agitation unless its compatibility with the method has been demonstrated. If the solution will be used in a sensitive in vitro assay, verify the final pH, concentration and solvent compatibility.
Handling should follow the current SDS and institutional chemical-risk assessment. Appropriate precautions generally include a certified fume hood or suitable local containment, nitrile gloves, safety goggles and a laboratory coat. Avoid aerosol generation and direct contact with the powder or solution. Dispose of contaminated materials through approved institutional chemical and laboratory-waste procedures.
Technical Specifications and Molecular Attributes
| Attribute | Specification |
|---|---|
| Product | KPV, 10 mg, supplied with bacteriostatic water |
| Common designation | KPV; α-MSH(11–13) fragment |
| Sequence | H-Lys-Pro-Val-OH |
| Residue count | 3 amino acids |
| IUPAC name | Full systematic peptide name should be confirmed on the CoA; sequence notation is preferred for procurement |
| CAS Registry Number | 67727-97-3 is widely reported, but verify the exact form against the supplier’s CoA |
| Molecular formula | C₁₆H₃₀N₄O₄ |
| Average molecular mass | Approximately 342.43–342.44 g/mol |
| Monoisotopic mass | Approximately 342.2267 Da |
| Physical state and colour | Lyophilised white to off-white powder |
| Solubility profile | Aqueous reconstitution may be feasible; solvent and buffer compatibility require assay-specific validation |
| Typical purity | Proposed target ≥99.0% by RP-HPLC; verify the actual lot-specific result |
| Identity testing | LC-MS, ESI-MS or high-resolution MS |
| Companion reagent | Bacteriostatic water; volume and formulation should be confirmed on the packaging |
| Long-term storage | Typically −20°C, sealed and protected from light and moisture |
The sequence, formula and molecular mass are broadly consistent across peptide-reference sources, although public catalogue records contain conflicting CAS information. Procurement teams should require reconciliation of the exact chemical form before approving the material.peptidebiologix+2
Pharma Research .eu: Your Premier EU Vendor for High-Purity Reagents
Pharma Research .eu can position KPV as a documented European laboratory reagent for analytical chemists, biochemists and laboratory managers requiring a defined short peptide. The product file should include a batch-specific CoA, SDS, sequence designation, purity result, identity data, terminal-group and salt-form information, and storage instructions.
Any claim that Pharma Research .eu operates an ISO 9001-certified quality-management system should be supported by a current certificate identifying the issuing body, scope and validity. Claims concerning discreet or temperature-controlled logistics across EU member states should likewise be verified for the destination, carrier route, packaging and applicable transport requirements.
A quality-focused supplier should be able to discuss:
-
KPV’s Lys-Pro-Val sequence and terminal groups.
-
Free-peptide versus acetate or other salt form.
-
RP-HPLC purity and LC-MS identity testing.
-
Residual solvents, moisture and elemental-impurity reporting.
-
Packaging configuration and container-closure integrity.
-
Compatibility of bacteriostatic water with analytical workflows.
-
Storage, transport and documentation requirements.
Pharma Research .eu should therefore be described as a potential European source for research-grade KPV, with vendor-specific certification and logistics statements verified through current records. The material is intended strictly for controlled laboratory research and analytical use by qualified personnel under applicable institutional procedures.
MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.


Reviews
There are no reviews yet.